Pin Fin Apparatus Manufacturer,Supplier and Exporter in India

Product Code : EL-HTL-11082
Lab Equipments Ambala is a leading Pin Fin Apparatus Manufacturer,and suppliers in Ambala, Pin Fin Apparatus Manufacturer,and suppliers in South Africa, Pin Fin Apparatus Algeria (Algiers), Pin Fin Apparatus Angola (Luanda), Pin Fin Apparatus Argentina (Buenos Aires), Pin Fin Apparatus Armenia (Yerevan), Pin Fin Apparatus Australia (Canberra), Pin Fin Apparatus Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Specifications:
Three pin fins-
  a) M. S.
  b) Brass
  c) Al
Channel- 150mm x 100mm x 1000mm
Blower – run by f.h.p. motor.
Orifice meter along with water manometer to measure airflow.
Voltmeter and ammeter to measure power input.
Cr- Al thermocouple with 6 tapings along with temperature indicator.
Dimmerstat to control power input.
A band heater to heat the pin fin.

Description :-
The apparatus consists of a channel in which the pin fin is tested in both natural as well as forced convection. 
The channel is connected to the suction of blower. 
The blower is operated to touch the pin fin in forced convection only. 
In natural convection, the window above the pin fin is kept open to the atmosphere. 
Five thermocouple tapings are given along the length of the fin. 
Thus the temperature distribution along the length can be distinguished. 
Also natural and forced heat transfer co-efficient, effectiveness, etc. can be found out.

A technical manual accompanies the unit.

Services required:
220v, stabilized single phase supply along with earthing Connection.
Floor area 2m x 1m x 1m height.

   